Actuate every valve on your P&ID. Torque-sized. Fail-safe confirmed. ESD battery calculated at quotation.
Electric, pneumatic, hydraulic, and gas-over-oil actuators with digital positioners — ATEX Zone 1, SIL 2/3 per IEC 61511 — for every valve type and every fail-safe requirement. Torque calculation and ESD battery sizing delivered with the quotation, before your purchase order is placed.
The engineering detail that separates actuator supply from actuator selection.
Valve torque data sheet, worst-case operating condition (max ΔP at minimum supply), safety factor applied (typically 1.25–1.5×), and actuator output torque confirmed in writing — before your purchase order. Not after the actuator arrives and cannot move the valve.
For battery-backed electric ESD actuators, we calculate the battery capacity required for the specified number of full-stroke operations at the minimum ambient temperature. Battery specification confirmed at quotation stage with replacement interval recommended.
SIL 1/2/3 actuated valve packages (valve + actuator + solenoid) with combined PFDavg for the final element assembly. Partial stroke test (PST) configuration and coverage percentage documented. SIL certificate from TÜV or Exida supplied at the quotation stage.
Actuator mounting flange (ISO 5210 multi-turn / ISO 5211 quarter-turn) and stem coupler profile (square, rectangular, or keyed) confirmed against the valve manufacturer's top-works drawing before the actuator is ordered. Custom brackets and couplers where ISO standard mounting is not available.
Six actuator technologies. Sized to your valve. Matched to your fail-safe requirement and power supply.
Actuator Type 01 — Electric Multi-Turn
Electric multi-turn actuators for gate, globe, and rising-stem ball valves.
AC or DC electric motor driving a multi-turn output shaft through a spur or worm gearbox — for rising-stem gate valves, globe valves, and multi-turn ball valves. Integral controls with open/close/stop commands, local/remote selector, torque and travel limit switches, and position transmitter (4–20 mA or potentiometer). HART 7, Foundation Fieldbus, or Profibus PA field communication for DCS integration and remote diagnostics. Battery backup module for fail-safe operation on power loss. Stainless steel enclosure or aluminium with IP67/IP68 rating for coastal and offshore installations. Data logger recording torque signature for valve condition monitoring.
Three deliverables on every actuator order that most suppliers ask you to calculate yourself.
How we size every actuator — the five-step process we apply to every valve on your line list.
Obtain valve torque data
Identify worst-case operating condition
Apply safety factor
Select actuator and confirm output torque
Issue formal sizing calculation
Why torque sizing matters — the failure mode if you skip it
Mounting compatibility — ISO 5211 confirmation before the order
Actuated valve packages across six industries — each with its own fail-safe requirement and approval framework.
- Pneumatic spring-return, DTT solenoid, SIL 2 for wellhead ESD[cite: 12]
- Gas-over-oil for remote pipeline valves (no instrument air or power)[cite: 12]
- ATEX II 1G Zone 0 for wellhead zone classification[cite: 12]
- ESD battery backup for electric actuators in offshore applications[cite: 12]
- FF H1 digital positioners for control valves in DCS-controlled units[cite: 12]
- SIL 3 ESD packages: 1oo2 solenoid voting, combined PFD documented[cite: 12]
- Electric multi-turn for gate valve MOV (motor-operated valve) remote control[cite: 12]
- ATEX Zone 1, stainless enclosure for corrosive atmosphere near process[cite: 12]
- Cryogenic-rated lubricants, −60°C ambient, SS enclosure[cite: 12]
- Heater provision to maintain actuator internals above −40°C[cite: 12]
- Scotch-yoke pneumatic for large-bore (24"–56") LNG isolation[cite: 12]
- Fast-acting spring-return for BOG pressure control (≤5 second close)[cite: 12]
- Electric multi-turn with VFD for slow-close steam turbine bypass[cite: 12]
- Battery backup ESD: 10-second close on turbine trip — calculated[cite: 12]
- Modulating electric with 4–20 mA HART positioner for drum level control[cite: 12]
- IP68 stainless for outdoor/weather-exposed cooling water valve actuation[cite: 12]
- GRP enclosure for Cl₂, HCl, and caustic atmosphere[cite: 12]
- Profibus PA positioners for Siemens PCS 7-controlled petrochemical units[cite: 12]
- Diaphragm actuators for hygienic/sanitary control valves[cite: 12]
- Stainless steel trim and PTFE-lined pilot for corrosive control service[cite: 12]
- IP68 buried-service electric actuators for municipal distribution[cite: 12]
- Modulating for chlorine dosing and pH control valves[cite: 12]
- Non-ATEX (safe area) for water treatment — cost-optimised[cite: 12]
- Bluetooth configuration for hard-to-access installed actuators[cite: 12]
The actuator, mounting, approval, and safety standards confirmed at specification before every order is placed.
| 🛠️ ACTUATOR & MOUNTING STANDARDS | |
|---|---|
| ISO 5210 | Mounting dimensions for multi-turn valve actuators. Stem categories A, B, C, D, E for rising/non-rising stems. |
| ISO 5211 | Mounting dimensions for part-turn (quarter-turn) valve actuators. F05 through F40 flange categories. |
| EN 15714 | Industrial valves — actuator types and operating conditions. Part 1 (electric multi-turn), Part 2 (electric part-turn), Part 3 (pneumatic). |
| IEC 60529 | Degrees of protection provided by enclosures (IP Code). IP54, IP65, IP66, IP67, IP68 per application. |
| NEMA 4X | US equivalent enclosure rating — watertight, dustproof, corrosion-resistant — used on North American specifications. |
| ⚡ HAZARDOUS AREA APPROVAL | |
|---|---|
| ATEX 2014/34 | EU directive for equipment in explosive atmospheres. Category 1G (Zone 0), 2G (Zone 1), 3G (Zone 2). |
| IEC 60079 | Explosive atmospheres — equipment design, testing, and marking. IECEx system for international recognition. |
| Ex d (IIC) | Flameproof enclosure — most common protection method for electric actuators in Zone 1. IIC for hydrogen service. |
| Ex ia (IIC) | Intrinsic safety — for solenoid valves and positioners in Zone 0 requiring the highest protection level. |
| FM / CSA | Factory Mutual (FM) and Canadian Standards Association (CSA) approvals for North American specifications. |
| 🛡️ FUNCTIONAL SAFETY & CONTROL | |
|---|---|
| IEC 61511 | Functional safety — Safety Instrumented Systems for process industries. Defines SIL requirements for final elements. |
| IEC 61508 | Functional safety of E/E/PE systems. Underlying standard for SIL certification of individual components. |
| HART 7 | IEC 62090 — field communication protocol for positioners and actuators. Device diagnostics from DCS. |
| IEC 61158 | Foundation Fieldbus H1 and Profibus PA — digital field bus for smart positioners and valve controllers. |
| API 6D | Pipeline valves — actuator requirements for ESD ball and gate valves on pipelines per API 6D Annex A. |
Actuated valve packages from Istanbul to the Middle East, Central Asia, and Africa — torque-sized, documented, and ready for installation.
Actuated valve packages exported to 40+ countries from Istanbul since 2001.
Questions valve engineers and procurement teams ask before placing their first actuated valve package order.
Documentation — every actuated valve package
Complete the valve automation package from the same supply source.
Ball, gate, globe, butterfly, check, and PSV to API 6D, API 600, and ASME B16.34. EN 10204 3.1, NACE, ATEX, SIL documentation standard.
Pressure, temperature, level, flow, and gas detection. HART 7/FF/Profibus PA. SIL 1/2/3. Hookup drawings and loop diagrams per tag.
API 610 centrifugal, API 674 triplex, API 675 metering. API 682 seal selection at quotation. Hydraulic duty confirmation included.
PAUT/TOFD ultrasonic, digital radiographic, MT, ET, PT. ASME V, API 1104, EN ISO. Calibration blocks included with every system.
Submit your valve list for actuation. Torque sizing and quotation returned within 24 hours.
Valve tag · valve type · size · pressure class · end connection · torque data reference (or valve model) · fail-safe requirement (FC/FO/FL) · power supply available · ATEX category · SIL requirement · number of ESD operations · minimum ambient temperature. We size, select, calculate, and quote — with torque calculation delivered alongside the commercial quotation.